SN

SMI No.

Description

Date

File no.

99.    SMI/101 Method for confirming that the pin is nitrided and procedure for replacement of journal pin (Pt.No.451) Tap changer No.2 type HBB make. 29.10.82 EL/3.2.30/JCG
100.         SMI/102 Procedure for repairing the defective welds of transformers fitted on AC electric loco 22.12.82 EL/3.2.1
101.         SMI/105 Lubrication to groove of piston skirt (Pt.2304) of Tap Changer type No.32 HBB make. 8.4.83 EL/3.2.30
102.         SMI/106 Cleaning of the selector after 10,000 km  run of tap changer No.32 HBB make 10.6.83 EL/3.2.30
103.         SMI/108 Setting of simplified battery charger on AC electric locomotives for 110 V DC battery (50 cells) 12.12.83 EL/3.2.12/Thy
104.         SMI/109 Setting of battery charger type BCF3, BCF6 and BCF7 of M/s Control and drives make and provided on AC locomotives for 110V battery (50cells) 17.12.83 EL/3.2.12/1
105.         SMI/110 Silicon  grease treatment on the insulators of circuit breaker type DBTF 30 I 250 5.12.83 EL/2.2.2
106.         SMI/110A Silicon  grease treatment on roof line, panto mounting and pantograph insulation 17.5.83 EL/2.2.2CG
107.         SMI/111 Change of traction motor speed winding of exhauster motor (MPV) from 6pole to 4 pole enameled wire windings. Dec. 1983 EL/3.2.70
108.         SMI/112 Maintenance instruction for electric loco and EMU battery (lead acid type) of 90A and 75 Ah capacity at 5 hr. rate covered by IS:7660 3.2.84 EL/6.7.8
109.         SMI/113 List of various torque values and assembly  tools/adopter to be used at various locations in tap changer No.32 type and air blast circuit  breakers(DJ) DBTF 30 250 type of HBB makes. 16.3.84 EL/3.2.30
110.         SMI/114 Method of evaluating crimped joint performance. ---------- EL/2.2.36
111.         SMI/115 Use of fire retardant paint for equipment complete of EMU 21.2.84 EL/4.3.25
112.         SMI/116 Maintenance of pantograph wearing  strips on 25 KV  AC electric multiple units 22.3.84 EL/2.2.25
113.         SMI/117 Breakage of  needle bearing roller (Pt. 2311) of tap changer type No.32 of HBB make 4.4.84 EL/3.2.30/CG
114.         SMI/118 Tightening of connecting terminal (1206) with cut (1207) on contact pins (1208 & 1209) of tap changer No.32 of HBB make 5.5.84 EL/3.2.30
115.         SMI/119 Periodic application of lubricating oil on balance wheel of clock mechanism of BBC make time  lag  relay Q44, Q118, etc. 23.5.84 EL/3.2.10/Gen
116.         SMI/120 Maintenance of main transformer oil in service 23.11.84 EL/3.2.1/3
117.         SMI/121 Revised characteristics for new insulation oil for locomotive/EMU transformer and additional tests for maintenance of oil in service 6.2.85 EL/3.2.1/3/J6
118.         SMI/122 Additional insulation over tap leads 22.4.85 EL/3.2.1/2/J6
119.         SMI/123 Torque values to be adopted for core bolts of loco transformers 22.4.85 EL/3.2.1/2/J6
120.         SMI/124 Specification for cork sheet gasket 22.4.85 EL/3.2.1/2/J6
121.         SMI/125 Primer and paint to be used for freight loco transformer 22.4.85 EL/3.2.1/2/J6
122.         SMI/126 Flushing of the stagnated oil in the neck portion of the  Loco transformers 22.4.85 EL/3.2.1/2/J6
123.         SMI/127 I-      Procurement specification for insulating oil II- Condition monitoring of insulating oil (for loco and EMU Tr. Only) 30.5.85 EL/3.2.1/3
124.         SMI/128 Tan Delta (Dissipation factor) measurements on traction motor armatures 19.6.85 EL/3.2.95/J3
125.         SMI/129 Replacement procedure for bevel gear 1924/1925 of No.32 Tap changer of HBB makes 29.7.85 EL/3.2.30/CG
126.         SMI/130 Damping adjustment of isolating drive complete (2400) of circuit breaker (DJ) type DBTF  30i250 of HBB make 01.1.86 EL/2.2/J-6            
127.         SMI/131 Special maintenance instructions for ensuring pick up and drop out for QCVAR Relay type VAG II/VAAII of English electric make 15.10.86 EL/3.2.10/5/J6
128.         SMI/132 Dismantling instructions of ball bearing (2058) from shaft (2056) of circuit breaker type DBTF 30i250 of M/s HBB 25.9.1987 EL/2.2.2/J-6
129.         SMI/133 Dismentling instructions of isolator rod part No. 6031 from isolator blade  head part No. 6001 of DBTF circuit Breaker

16.10.87

 
EL/2.2.2/J-6
130.         SMI/134 Replacement procedure of air motor support 20.10.87 EL/3.2.30/J6
131.         SMI/135 Dismantling instructions and fixture details for the removal of pinion (Pt No. 6101)  of crank shaft on  (SMGR) 21.10.87 EL/3.2.30/J6
132.         SMI/136 Instructions for testing the VCB type 20 CB for   travel records Jan 91 EL/3.2.61
133.         SMI/137 Maintenance of air dryer provided in pneumatic circuit breaker (VCB) type 20 CB GEL make Mar 91 EL/3.2.61
134.         SMI/138 Rev.-1 Condition monitoring of traction transformers by dissolved gas analysis May'2024 EL/3.2.1/3/J6
135.         SMI/139 Checking the capacitance of the capacitors in ac damping, dc damping and snubber circuits of silicon rectifiers used on electric locos 29.5.91 EL/3.2.135/J4
136.         SMI/140 Premature failure on nose suspension rubber sandwich block of traction motor 253  Br/BW/4601 AZ of BG AC EMUs if the clearance in the bogie sandwich block are not maintained within the stipulated limits 11.2.92 EL/4.6.7/J3
137.         SMI/141 Diametral clearance of suspension bearings on BG AC EMU axle 21.4.92 EL/1.3.10/J3
138.         SMI/142 Failure of capacitor terminals in surge voltage damping panels of silicon rectifier cubicles on ac electric locomotives 13.8.92 EL/3.2.135/J12
139.         SMI/143 Maintenance schedule for tap changer No.32 27.8.92 EL/3.2.30
140.         SMI/144 Flashing inside the selector of tap changer No.32 20.10.92 EL/3.2.30
141.         SMI/145 Crank shaft fracture of No.32 tap changer 20.10.92 EL/3.2.30
142.         SMI/146 Breakage of journal pin of SMGR  tap changer No.32 ABB make 20.10.92 EL/3.2.30
143.         SMI/147 Use of button head type of  grease nipple on auxiliary motors fitted on electric loco 30.10.92 EL/3.2.70
144.         SMI/148 Guidelines to identify genuine and spurious/reconditioned bearing Oct.92 EL/2.2..48
145.         SMI/149 Special instruction for surge on 3-phase AC auxiliaries 23.11.92 EL/3.2.70
146.         SMI/150 Ultrasonic testing of armature shaft of Hitachi Tractio Motor type HS 1050 Er/HS15250A. 23.11.1992 EL/8.11.17/J3
147.         SMI/151 Testing of brazing joint of field coils circuit of traction motor type TAO659 & HS 1050 ER/HS 15250 A 8.12.92 EL/3.2.5/J3
148.         SMI/152 General guidelines to follow for balancing of rotor and blower impellers 15.12.92 EL/3.2.70/J3
149.         SMI/153 Characteristic properties of enamel used on enamelled winding wires Feb 93 EL/2.2.82/J3
150.         SMI/154 Characteristic properties of insulating varnishes 17.2.93 EL/2.2.8.4
151.         SMI/155 Essential requirements of facilities to rewind 3-f AC Aux. Motors in loco sheds and rewinding shops 18.3.93 EL/3.2.70
152.         SMI/156 Rewinding processes for the armature of traction motor type HS 1050 EL/HS 15250 29.6.93 EL/3.2.172
153.         SMI/157 Condition monitoring of solenoids by surge comparison method 16.7.93 EL/2.2.51
154.         SMI/158 Code of practice for maintenance of transformer oil in service 1.2.95 EL/3.2.1/3
155.         SMI/159 Inhibited transformer oil 8.12.93 EL/3.2.1./3
156.         SMI/160 Measurement of backlash of traction motors 31.3.94 EL/3.2.172
157.         SMI/161(Rev’1’) Sealing of cradle cover of VCB 22.5.94 EL/3.2.61
158.         SMI/162(Rev’1’) Lubrication to air relay  valve and main piston Of VCB 24.4.95 EL/3.2.61
159.         SMI/163 Detection of rotor bar and end ring cracks on arno-converter and auxiliary motor by search coil and motor tester. 21.12.94 EL/3.2.11
160.         SMI/164 Code of practice for maintenance of loco transformer 1.2.95 EL/3.2.1
161.         SMI/165 Proforma for reporting failure of  transformer/ smoothing reactor 9.2.95 EL/3.2.1
162.         SMI/166 Ventilation of TAO 659 traction motor 3.2.95 EL/3.2.5
163.         SMI/167 Precautions while taping of busbars and fixation of clamps of traction motor stators 3.2.95 EL/3.2.5
164.         SMI/168 Copper busbars used in stator of TAO 659 traction motor 3.2.95 EL/3.2.5
165.         SMI/169 Cleaning of the commutator of TAO 659 traction motors in the locomotives 3.2.95 EL/3.2.5
166.         SMI/170 Check on main pole and interpole coils of TAO 659 traction motor 3.2.95 EL/3.2.5
167.         SMI/171 Fitment of MICALEX insulator on TAO 659 traction motor 3.2.95 EL/3.2.5
168.         SMI/172 Engineering practices for improving reliability of relays 24.2.95 EL/3.2.10/Gen
169.         SMI/173 Improvement in the reliability of interlocks used in control equipments 9.2.95 EL/3.2.10/Gen
170.         SMI/174 Improved maintenance practices for CLW make EP contactors 24.2.95 EL/3.2.7
171.         SMI/175 A Hole to Hole dimensions for main wearing strip of AM-12 pantographs 24.2.95 EL/2.2.25
172.         SMI/176 Fixing of armature spider of motor (KPC-1) frame 110 VDC on the shaft of compressor 3HC-55 30.3.95 EL/3.2.114
173.         SMI/177 Setting of QLM & QRSI relays for WAG7 Locos 29.3.95 EL/3.2.10/11
174.         SMI/178 Use of cork sheet gasket in place of rubber 3.4.95 EL/3.2.1
175.         SMI/179 Check points before charging/ commissioning of transformer fitted with BSES bushing Oct 95 EL/3.2.1
176.         SMI/181

Neutral setting of brush holder revolving ring of Traction Motor by electrical method known as KICK METHOD

30.05.1996

EL/3.2.5

177.        

SMI/182

Clearing of commutator surface after using new grade in place of old grade of carbon brush.

June 96

EL/2.2.70

178.         SMI/183 Procedure for proper tightening of suspension tube fixation bolts fitted on traction motor type TAO-659 and HS 15250 S Dec 96 EL/1.3.10
179.         SMI/184 Ascertaining the proper functioning including discharged rate of 1&  NRV used in the pneumatic circuit of electric loco Jan 97 EL/3.2.14
180.        

SMI/185  (Rev.1)

Amendment1, Amendment2

Rewinding materials for auxiliary motors (This supersedes SMI/98 of October 82) 30.10.2000 EL/3.2.70
181.        

SMI/186 with Amend-1, Amend-2 & Corrigendum of Amend-2.

Bonded rubber sandwich mounting for nose suspension of traction motor 16.4.14 EL/3.2.5
182.         SMI/188-A Graphite grease for use on main wearing strips of pantograph. Of pantograph 11.4.97 EL/2.2.25
183.         SMI/189 Wearing strips for pantograph AM12 type and of similar design May 1997 EL/2.2.25
184.         SMI/190 Malfunctioning of QRS Relay due to wrong connection/setting of RGEB May 97 EL/3.2.19
185.         SMI/191 Replacement of existing cables, connecting  PED & Motor connection Box with higher size cable on AC BG EMUs 26.5.97 EL/4.3.23.2
186.         SMI/192 Periodic maintenance of AM12 type pantographs 26.5.97 EL/2.2.1
187.         SMI/193 Engineering practices for improving reliability of cable head termination system for 25 KV AC Locos/EMUs 12.1.98 EL/3.2.21
188.         SMI/194 Special maintenance instructions of    Co-Co trimount bogie 14.1.98 EL/3.2.165
189.         SMI/195 Trouble shooting instructions for  tripping through QOP cases. 28.01.98 EL/3.1.3
190.         SMI/196 Cracking of centre pivot bottom cross plate in WAP1 Locomotives 21.1.98 EL/3.2.13/1
191.        

SMI/197(REV-1)

Amend. dated 26.07.2001

Driving techniques and use of proportionate brake application to prevent cases of wheel skidding on dual brake as well as pure air brake electric locomotives 21-6-2001 EL/3.2.19
192.         SMI/198 Lubrication schedule for improving reliability of AM-12 type of pantographs and of similar design Mar 98 EL/2.2.1
193.         SMI/199 General guidelines  to follow for balancing of rotors and cooling blowers in position Mar 98 EL/3.2.14
194.        

SMI/200(Revised)

Characteristic properties of impregnating resins and insulating varnishes Dec.'99 EL/2.2.8.4
   


For others, please click on below link 

SMI no. 1 to 100

 

SMI no. 201 to 300

 

SMI no. 301 onwards

        

   



 

 



Source : WELCOME TO RDSO CMS Team Last Reviewed on: 02-05-2024  

  Site Map | Contact Us | Disclaimer | Terms & Conditions | Privacy Policy Valid CSS! Valid XHTML 1.0 Strict

� 2016  All Rights Reserved.

This is the Portal of Indian Railways, developed with an objective to enable a single window access to information and services being provided by the various Indian Railways entities. The content in this Portal is the result of a collaborative effort of various Indian Railways Entities and Departments Maintained by CRIS, Ministry of Railways, Government of India.